The Portable Test Equipment consists of an integrated current and voltage source and electronic reference standard of accuracy class 0,05 % or 0,02%. Device is available in three-phase version PTE 2300 or single phase version PTE 2100.
Properties
- Laboratory and on-site meter measurements
- Easy evaluation of meters under precise load conditions, using the built-in compact current and voltage source
- Testing of meters with closed I-P links
- Automatic operation with predefined load points without the need for an external computer
- Each source channel can be programmed with user defined harmonic content or standardized signal test shapes
- Each source channel can be modulated with programmable Ripple control telegram
- Independent generation of single or three-phase loading conditions for testing, calibration and verification of meters
- Active, reactive and apparent energy measurement for three phase, 3 or 4-wire, systems with integrated error calculator and pulse output
- Capable to test the ratio and burden of CT/PT
Technical data
Power Source (built-in/specification per phase) |
|
Voltage | |
Range | 3 ... 300 V (phase to neutral) |
---|---|
Output power | 30 VA |
Accuracy | 0,015 % (PTE 2x00E); 0,035 % (PTE 2x00A) |
Distortion factor | < 0,3 % |
Resolution | 0,01 V |
Stability | < 0,005 % (within 60 min period @ time base 150 s) |
Current | |
Range | 1 mA ... 120 A |
Output power | 60 VA max @ 60-120 A / 1 V max @ 0-60 A (120 A output) 42 VA max @ 12 A / 5 V max (12 A output) |
Accuracy *1 | 0,015 % (PTE 2x00E), 0,035 % (PTE 2x00A) |
Distortion factor | < 0,3 % |
Resolution | min. 0,1 mA |
Stability | < 0,005 % (within 60 min period @ time base 150 s) |
Phase Angle | |
Range | 0° ... 360° |
Resolution | < 0,001° (45 … 100 Hz) |
Harmonics | |
Fundamental Frequency Range | 40 Hz ... 70 Hz |
Bandwidth | 30 … 2200 Hz |
Phase Shift | 0° … 360° |
Max. amplitude | 50 % (2nd ... 6th harmonics); 15 % (7th ... 40th harmonics) |
Ripple Control | |
Frequency Range | 100 ... 1600 Hz |
Modulation | 0 … 15 % |
Channels Selection | any combination of Voltage and Current channels |
General Specifications | |
Oper. Temperature | -10 ... +50 °C |
Storage Temperature | -20 ... +60 °C |
Operating Humidity | < 85 % at Ta<21°C; < 95 % at Ta<25°C (30 days / year spread) |
Power Consumption | approx. 550 VA |
Power Supply | 100 VAC ... 550 VAC |
Degree of Protection | IP-67 (closed case) |
Safety Requirements | Isolation protection: EN 61010-1:2001 Measurement category: 300 V CAT III, 600 V CAT IV |
Dimensions (W x D x H) |
470 x 370 x 180 mm (device) |
Weight (approx.) | 16,5 kg (device) / 5 kg (accessories) |
*1 in range 1 mA ... 30 mA related to 30 mA